  1. > Hi everybody,
  2.  
  3. Ho there Doug,
  4.  
  5. > If anyone is still plagued with the double-vbl problem on their Falcon/VGA, then
  6. > here's a permanent cure for it:
  7.  
  8. Cool.
  9.  
  10. > Look for the 3 black inductors just below the monitor port on the Falcon PCB. The
  11. > two leftmost inductors are the horizontal & vertical sync lines. The third is the
  12. > composite video signal. Remove the two on the left and replace them with a couple
  13. > of 75ohm resistors.
  14.  
  15. You don't have the U numbers for those guys, or are they hard to miss?
  16.  
  17. > After making this modification, the double-vbl problem will disappear.
  18.  
  19. That's great! I might do it one day... :-)
  20.  
  21. > The problem itself is simply (weak) echos on the vertical sync line bouncing
  22. > between the monitor and Falcon, sometimes setting off an extra vertical blank. The
  23. > load resistors eliminate the echos and allow the Falcon to stay in sync with the
  24. > monitor.
  25.  
  26. Sounds like it as I tried one of those external screen expanders and the problem 
  27. went away! :-)
  28.  